FIRE PROPERTIES
|
Foil:
- Non combustible tested to SANS 10177 Part 5
- Class 1 fire index rating - tested to SANS 10177 Part 3
- Class A1, s1, d0 - tested to EN 13823
- EUROCLASS A1 - EN 13501-1
- Tested to ASTM E-84
- Smoke Development Index: 5
WMF:
- Non combustible - tested to SANS 10177 Part 5 -
- Tested to ASTM E-84
- Flame Spread Index: 20
- Smoke Development Index: 15
|
THERMAL PROPERTIES
|
|
Contributes to indoor comfort and life long energy savings by reducing heat loss/gain
due to the inherent thermal insulation properties.
|
ACOUSTIC PROPERTIES
|
|
Offers exceptional acoustic properties & enhances indoor environmental quality
by absorption of noise.
|
APPLICATIONS
|
Industrial roof insulation:
- over purlin installation (new buildings)
- between purlin installation (existing buildings)
|
DURABILITY
|
- Odourless, inert and fully compatible with all standard building materials & components
- Will not promote corrosion of steel, copper or aluminium
- Will not sustain vermin
- Will not breed or promote fungi, mould or bacteria
- Non-hygroscopic
- Dust settlement will not hamper the products performance
|
PHYSICAL PROPERTIES (Click on Image to enlarge)
|

|
TOOLS NEEDED FOR INSTALLATION
|
|
Straining wires, G-clamps, Galvanized hoop irons, Pop rivets, Drill, Heavy duty
staple gun, 10 mm wire staples.
|
INSTALLATION INSTRUCTIONS
|
- When installing the blanket in new buildings over purlins ensure that the straining
wires are placed 300 mm apart.
- Affix to the roof apex and unroll the blanket longitudinally taking out any slack
and attach to the bottom purlin.
- To join the blankets fold up the overlapping foil edges and staple, fold the join
over and staple again.
- Precaution to be taken when installing in windy conditions.
|
HANDLING & STORAGE
|
|
Store product undercover, and in dry conditions. Store flat. Handle with care, especially
on the edges and corners, which can be damaged if subject to sharp or heavy impact.
Do not apply excessive pressure, for example by standing or sitting on the product,
as permanent damage may be caused.
|
ARCHITECTURAL SPECIFICATION
|
|
Install (50/75/100/135)mm thick, non-combustible, lightweight “Factorylite” building
insulation with (reinforced foil, white metalized foil/black metalized foil) facing
on (one/both) sides, with thermal resistance of (1.28/1.92/2.56/3.46)m2K/W. Install as
per manufacturer’s specifications. |
Isover reserves the right to alter or amend product specification without notice.
The information given in this publication is correct to the best of our knowledge
at the time of publication. Whilst Isover will endeavour to ensure publications
are up to date, it is the users’ responsibility to check with us that it is correct
prior to use.
|