QUALITY MANAGEMENT SYSTEM
|
|
Isover products are manufactured according to ISO 9001:2008.
|
FEATURES & BENEFITS
|
Life long energy savings
- Excellent thermal & acoustic properties
- Maintenance free
- Long product life - will not readily age
- Significantly reduces heat loss/gains
- Made to size to reduce wastage
- Zero ozone depleting potential(ODP)
|
FIRE PROPERTIES
|
Foil:
- Class 1 fire index rating - tested to SANS 10177 Part 3
- Class A1, s1, do according to EN-13823
- EUROCLASS A2 - EN 13501-1
- Tested to ASTM E-84
- Flame Spread Index: 10
- Smoke Development Index: 0
WMF:
- Tested to ASTM E-84
- Flame Spread Index: 20
- Smoke Development Index: 15
|
THERMAL PROPERTIES
|
|
Contributes to indoor comfort and life long savings by reducing heat loss/gain due
to the inherent thermal insulation properties.
|
ACOUSTIC PROPERTIES
|
|
Offers exceptional acoustic properties & enhances indoor environmental quality
by absorption of noise.
|
APPLICATIONS
|
- Multi-purpose wall cladding:
- Multi-purpose wall cladding:
- Recommended to be installed in a grid system.
- Over purlin roof insulation for new buildings or in a supporting grid system for
existing buildings
- Use 80 kg/m3 density in horizontal applications
|
DURABILITY
|
- Odourless, inert and fully compatible with all standard building materials &
components
- Will not promote corrosion of steel, copper or aluminium
- Will not sustain vermin
- Will not breed or promote fungi, mould or bacteria.
- Non hygroscopic
- Dust settlement will not hamper the products performance
|
PHYSICAL PROPERTIES (Click on Image to enlarge)
|
|
TOOLS NEEDED FOR INSTALLATION
|
|
Boards are manufactured to length – a sharp knife will be required should cutting
be necessary.
|
INSTALLATION INSTRUCTIONS
|
Take care when installing in windy conditions.
- When installing over purlins, a C clip/metal saddle must be inserted through the
board so that the roof sheet clip is fixed to the structure and not to the board.
- Use H sections or T sections to span between the purlins to support the board along
the longitudinal joint. Minimum recommended face width of T or H section - 35 mm.
- For retro-fit roof insulation installations, it is recommended that Factoryboard
be installed as a ceiling in a standard suspended grid system.
|
HANDLING & STORAGE
|
|
Store product undercover, and in dry conditions. Store flat. Handle with care, especially
on the edges and corners, which can be damaged if subject to sharp or heavy impact.
Do not apply excessive pressure, for example by standing or sitting on the product,
as permanent damage may be caused.
|
ARCHITECTURAL SPECIFICATION
|
|
Install (25/40/50)mm thick, rigid “Factoryboard” as an aesthetic, acoustic and thermal
(wall cladding/suspended ceiling/over purlin roof insulation). Density 80 kg/m3
faced with (reinforced foil/white metalized foil/black metalized foil/white embossed
vinyl/black non-woven glass tissue). Install as per manufacturer’s specifications.
|
Isover reserves the right to alter or amend product specification without notice.